At the end of June 2023, the National Institute of Environmental Research (NIER) of South Korea published three documents to provide guidance for enterprises in the approval of biocidal products. In the following are the details of these documents:
1. Guidance for environmental data submission
-
Table of environmental data submission
|
Category |
Data Type |
Mandatory/Optional |
Items |
Instructions for Mandatory/Optional Data Submission Requirements |
|
|
Hazardous Information |
Ecological Effect |
General Data |
Mandatory |
Ecotoxicological information of product used for ecotoxicity classification |
Provide toxicological information, classification and labeling information |
|
General Data |
Optional |
Effect on other non-target organisms |
- |
||
|
Test Data |
Optional |
More information of ecological effects |
Meet one of the following conditions: 1) Hazard assessment was conducted based on the results of ecological effect testing, revealing the presence of hazards or potential, ongoing exposure possibilities in the evaluation outcome. 2) According to relevant regulations on the classification and labeling of chemicals, where there is insufficient valid data for the classification of individual components of a mixture, or when there is evidence of synergistic effects among the components. |
||
|
Fate and behaviour in the environment |
General Data |
Mandatory |
Provide estimated values of environmental emissions based on intended usage |
Provide emissions of different environmental mediums based on the environmental emission of products in its production and usage stage |
|
|
Test Data |
Optional |
Fate and behaviour in the environment |
Meet the following conditions: Hazard assessment was conducted based on fate and behaviour in the environment test results, revealing the presence of hazards or potential, ongoing exposure possibilities in the evaluation outcome. |
||
|
Environmental residue and monitoring data |
Meet all of the following conditions: 1) If the substances, degradation products, or other hazardous substances in biocidal products may impose an impact on the distribution and decomposition characteristics of the environment, monitoring is required. 2) Hazard assessments are conducted based on fate and behaviour in the environment testing results. The hazard assessment result reveals the presence of hazards or potential, persistent exposure possibilities. |
||||
|
Hazard Information |
General Data |
Mandatory |
Dose-effect analysis and derivation of PNEC |
Provide the Predicted No Effect Concentration (PNEC) and the calculation method of various environmental compartments |
|
|
Exposure assessment |
Provide the Predicted Environmental Concentration (PEC) of environmental compartments by using environmental behavioral models |
||||
|
Risk assessment |
Provide the risk assessment result of various environmental compartments |
||||
|
Environmental hazard assessment results |
Provide the risk assessment result of various environmental compartments |
||||
- Data submission scope:
- All biocidal products are required to submit environmental data regardless of whether they contain any of the following substances: toxic substances, restricted substances, prohibited substances, substances under priority control, permitted substances, or substances under emergency response, and regardless of their concentration.
- Generally speaking, components of mixtures affecting its classification are required to submit relevant data when its hazard concentration in aquatic environment reaches or exceeds 0.1%. However, if there is evidence proves its environmental hazard, relevant environmental data is required to submit even if its concentration below 0.1%.
- It is not necessary to submit environmental data for biocidal products with low hazards based on NIER (National Institute of Environmental Research) or products exempted from registration or notification according to the Act on the Registration and Evaluation of Chemicals (K-REACH).
- Enterprises shall confirm whether their products may contain substances having synergism function based on the Consumer Chemical Products and Biocides Safety Act (K-BPR). If enterprises couldn't find any relevant data on synergism, they may submit reports involving relevant database and keywords.
- 'Recognized data:
-
- International data: data that has been assessed and published by international authorities (such as EU, IARC,OECD and so on) or governments (including members of EU and OECD);
- Data in Korea: data assessed and published in accordance with the Act on the Registration and Evaluation of Chemicals (known as K-REACH).
Note: Material Safety Data Sheets (MSDS) and Product Safety Data Sheets (PSDS) are not accepted due to their unreliability.
2. Guidance on product name and label
- Generally speaking, product names must be described in Korean; if there are non-Korean names, the Korean name should be in a larger font size. (The content of biocidal products may be expressed in English units of measurement, such as mol, M, etc.)
- Product name may not exaggerate the efficacy or performance of a product, or potentially mislead consumers.
- Product label shall indicate product name, type of biocidal products, active substances (including active substance name and its percentage), expiration date, efficacy, and usage precautions.
- The following circumstances shall be prohibited:
-
- The product name cannot be identical to any existing product in sales. It must not contain titles such as celebrities or experts to improve the product's image, and it must not use names that could lead to the product being mistaken for another;
- Superlative characters including “the first” and “the best” are not allowed;
- Expressions that may lead people to believe the product is non-toxic or environmentally friendly is not allowed. Expressions implying multiple uses of the product are also prohibited.
3. Data submission on product efficacy/efficacy test (concentration and co-formulants)
- When applying for the approval of biocidal products, documents shall be submitted based on their usage quantity (concentration), efficacy data, standard dosage and usage method.
- Data submission covers testing data and general data while testing data shall prevail. General data may be submitted such as similar ingredients or usage method, targeted biological species.
- Concentration settings without scientific proof will not be accepted, such as usage concentration of other biocidal products or usage standard recommended in Korea and foreign countries.
- In the following circumstances, data submission may be exempted:
-
- For certain biocidal products that cannot conduct experiments under specific conditions due to their uniqueness, relevant information may be submitted;
- In cases where a product involving several targets and testing data is only required for certain species, reasonable supporting documents shall be provided.
The test data of co-formulants is not mandatory. However, additional data may be required to submit for biocidal components having disinfection function.