Update the Australia Workplace Exposure Limits for Airborne Contaminants-Latest Version as of December 2026

Update Date: Nov 19, 2026

From 1 December 2026, persons conducting a business or undertaking (PCBUs) in Australia must comply with the Workplace Exposure Limits for Airborne Contaminants (WEL list). Until then, the Workplace Exposure Standards for Airborne Contaminants (WES list) continue to apply. Changes from the WES list to the WEL list. The Workplace Exposure Standards for Airborne Contaminants are renamed the Workplace Exposure Limits for Airborne Contaminants. Changes to individual exposure limits and notations. decreases or increases in exposure limit values; addition or removal of exposure limit types; merging or splitting of airborne contaminant groups; changes to the names of airborne contaminant entries; and addition or deletion of airborne contaminant entries. 31 new airborne contaminant entries have been added, such as barium sulfate, diacetyl, 1,3-dioxolane, 5-nitro-o-toluidine and glyoxal, while the following 6 airborne contaminant entries have been deleted. aldrin, chlordane, DDT (dichlorodiphenyltrichloroethane), dieldrin, endrin and heptachlor. Non-threshold genotoxic carcinogens (NTGCs) in the WEL. 33 airborne contaminants have been confirmed as non-threshold genotoxic carcinogens (NTGCs) and removed from the WEL list to a new list; from 1 December 2026, no workplace exposure limit will be set for them. Where NTGCs are present in the workplace, their use must be eliminated, or replaced with safer alternatives where possible, or the risk must be reduced to the lowest level reasonably practicable. Where NTGCs are used or generated and fall under Schedule 10 or Schedule 14 of the Model WHS Regulations, the corresponding compliance obligations must also be met; see the Australian Model Work Health and Safety Regulations for details. Changes to advisory notations. the sensitizer (SEN) notation has been split into skin sensitization (DSEN) and respiratory sensitization (RSEN); a new ototoxicity (OTO) notation has been added; and the carcinogenicity (CARC) notation has been removed. To find out whether an airborne contaminant in the workplace is carcinogenic or suspected to be carcinogenic, consult its Safety Data Sheet (SDS) or the new Hazardous Chemicals Information System (HCIS).The new HCIS is a guidance tool released by Safe Work Australia to support the WEL transition effective 1 December 2026. It displays, on a single page, the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) classification information and WEL data for a chemical, helping chemical manufacturers, importers and users determine the hazardous properties of chemicals and classify, label and prepare Safety Data Sheets (SDS) in accordance with GHS and WHS regulations. HCIS is available at https.//hcis.safeworkaustralia.gov.au/. During the transition period, the current WES must continue to be observed, ensuring that workplace exposure to the airborne contaminant does not exceed the current WES limit.

ChemRadar Copyright Disclaimers:

1. All texts, graphics, videos and audios with "Source: ChemRadar" on this website are copyrighted by ChemRadar. Without authorization, no media, website or individual is allowed to reproduce, link, distribute, publish, or copy any content in this website. Other media, website with our authorization shall indicate "Source: CIRS Group" when downloading or using relevant contents. Unauthorized actions will be persecuted.

2. Texts and graphics on thie website without "Source: ChemRadar" are reproduced for further information but not imply the endorsement of views or autheticity of its content. Other media, websites or individuals download or use relevant content shall remain its "Source" as prescribed in this website and bear corresponding legal responsibilities. Any unauthorized alternation to "Source: ChemRadar" may be persecuted. If you have any questions about relevant content on this website, please contact us.

3. If any content reproduced on ChemRadar raises copyright or other related issues, please contact us within two weeks.

4. CAS and CAS Registry Number are registered trademarks of the American Chemical Society. Any reference to such identifiers is made solely for the purpose of identifying chemical substances. ChemRadar is an independent platform and is not affiliated with, sponsored by, endorsed by, or an authorized partner of CAS or ACS. Based on CIRS’s current review, the identifiers displayed on this platform were not obtained directly from CAS REGISTRY or any CAS subscription product or service. They were collected from governmental regulatory publications and other independent third-party sources. Users should independently verify the information before relying on it.

events
Hot Courses
View More
Disclaimer
1.
CIRS aims to keep the content of this site accurate and up to date. However, CIRS makes no warranties or representations regarding the quality, accuracy, completeness or reliability of information on the site.
2.
In no event shall CIRS assume or have any responsibility or liability for any information on this site or for any claims, damages or losses resulting from their use.
3.
CIRS reserves the right, at our discretion, to change, modify, add to, or remove portions of information on this site at any time without notice.
4.
CAS and CAS Registry Number are registered trademarks of the American Chemical Society. Any reference to such identifiers is made solely for the purpose of identifying chemical substances. ChemRadar is an independent platform and is not affiliated with, sponsored by, endorsed by, or an authorized partner of CAS or ACS. Based on CIRS's current review, the identifiers displayed on this platform were not obtained directly from CAS REGISTRY or any CAS subscription product or service. They were collected from governmental regulatory publications and other independent third-party sources. Users should independently verify the information before relying on it.
icon-server
message
in